Southern Pump Services Engineering limited provide a wide range of pump control panels suitable for package pump station control our standard range of single and dual pump control panels include the following equipment as standards.
Our control panels are designed and built in the UK using only industrial quality components and come with full technical backup.
Single pump control panel starter; our control panel are designed to operate 1 No submersible pump automatically via float switches, probes or ultrasonics mounted in the sump or tank.
The pump control panel requires 2 No float switches to operate as above, those being;
i) Stop float
ii) Start float
As an optional extra a third floatswitch may be used to detect high-level conditions and give an alarm.
The pump control panel is housed as standard, in an I.P.55 mild steel enclosure with a stove enameled RAL 7032 finish.
1-Door interlocked isolator, pad lockable in the off position
1-Set of H.R.C motor protection fuses
1-Triple pole contactor for Direct On Line starting
1-Triple pole thermal overload relay
1-Control transformer with 24v secondary and fuse protection
1-Hand-Off-Auto selector switch
1-Pump running indication lamp-coloured green
1-Pump overload tripped indication lamp-coloured amber
1-Set of engraved labels
1-Set of identified terminals
Dual pump control panel starter; our control panel are designed to operate 2 No submersible pumps automatically via float switches, probes or ultrasonics mounted in the sump or tank.
The pump control panel requires 3 No float switches to operate as above, those being;
i)Stop float
ii)Start float
iii)Assist start float
As an optional extra a fourth floatswitch may be used to detect high-level conditions and give an alarm.
The pumps can run on a duty/assist or duty/standby principle, which enables the two pumps to run together or as a backup should the duty pump fail.
The pump control panel is housed as standard in an I.P.55 mild steel enclosure with a stove enameled RAL 7032 finish.
1 - Door interlocked isolator; pad lockable in the off position
2 - Sets of H.R.C. motor protection fuses
2 - Triple pole contactors for Direct on Line starting
2 - Triple pole thermal overload relays
1 - Control transformer with 24v secondary and fuse protection
2 - Hands - Off - Auto selector switches
1 - Automatic changeover relay to alternate the duty pump after each operation
2 - Pump running indication lamps - coloured green
2 - Pump overload tripped indication lamps - coloured amber
1 - Set of engraved labels1 - Set of identified terminals
Our Fix Land line Dial-Out telemetry control panel is designed to monitor and alert of any alarm conditions that are programmed to the unit; the system is protected with battery backup.
The Fix Land line Dial-Out telemetry control panel unit has three alarm inputs which are normally used to monitor the following conditions.
1: Pumps or Pump tripped
This alarm condition would send a message out should any of the pumps trip out on overload or any other type of pump protection fitted.
2: High Level Alarm Condition
The high-level alarm circuit would be from the 12vdc supply, so should the mains fail and the water level rise and set the high level alarm off the unit would still transmit the alarm.
3: Pump Station Healthy
This alarm function is use to monitor the fault signals above and has a delay timer fitted on the signal, when the alarm unit is commissioned and no alarm signals are on, after a preset time the dial out unit will call and inform you that the pump station is healthy, (if an alarm is raised for a pump trip this fault condition would have to be reset on the control panel, but if an alarm is raised for high-level condition the unit will dial out. Should this alarm condition only be for a short period of time say 30min and then the level of water in the station fall the alarm unit will send the pump station healthy signal out to cut down on any wasted call outs.
Our GSM Dial-Out telemetry control panel is designed to operate via a mobile phone network; this unit can run on any of the standard networks on a pay as you go system.
You can top up the credit from a standard card and you can check what credit is remaining on the unit at any time. You can call the unit up at any time to check the alarm status; the GSM Dial-Out telemetry control panel unit unit has 6 inputs for alarms.
This type of remote alarm will only send text messages to a mobile phone; it will not dial a fix landline phone.
1: Pumps or Pump Tripped
This alarm condition would send a message out should any of the pumps trip out on overload or any other type of pump protection fitted.
2: High Level Alarm Condition
The high-level alarm circuit would be from the 12vdc supply, so should the mains fail and the water level rise and set the high level alarm off the unit would still transmit the alarm.
3: Pump Station Healthy
This alarm function is use to monitor the fault signals above and has a delay timer fitted on the signal, when the alarm unit is commissioned and no alarm signals are on, after a preset time the dial out unit will call and inform you that the pump station is healthy, (if an alarm is raised for a pump trip this fault condition would have to be reset on the control panel, but if an alarm is raised for high-level condition the unit will dial out. Should this alarm condition only be for a short period of time say 30min and then the level of water in the station fall the alarm unit will send the pump station healthy signal out to cut down on any wasted call outs.
Should you have a pumping station requirement you will need to have certain information available for us to quote by complete our online Pump Station Enquiry Form this will enable us to provide you with a proposal our proposals are normally turned around within 24hrs. Click here for further guidance; please remember to complete all fields.
Southern Pump Services install and maintain foul water pumping stations.
Our sewage pumping stations can be either above ground or below ground, and suitable from small domestic applications to large installs.
These submersible pumps are available in 220v or 400v electrical supply, which can be supplied or alternatively installed by our Southern Pump Services engineers.
At southern pumps we provide comprehensive after sales support providing a second to none service to keep your pumping station working smoothly.
At Southern Pump Services we have tankers and engineers available 24/7 – 365 when your pump station fails.
We've been using Southern Pump Services for over 10 years now, we wouldn't use anyone else